Model TH-890 Continuous Emission Monitoring System

Model TH-890 Continuous Emission Monitoring System
Product Detailed
1. Direct pumping sample guarantee accuracy 2. PLC control system 3. Data can be stored for more than 5 years

Model TH-890 includes gas extractor, flue gas monitor, flue dust monitor, and data collecting processor.

Applications:1. Public utilities 2. Co-generation3. Refineries 4. Turbines5. Waste incinerators 6. Wood waste boilers7. Lime kilns8. Recovery boilers9. Power boilers  10. Landfills11. Cement kilns 12. Sulfur recovery units

Specifications:

Equipment Data Sheet

Item

Model

Parameter

TH-890 CEMS Working Environment

TH-890

Environmental Temperature -20°C~60°C

Indoor Environmental Temperature 5°C~35°C

Relative Humidity less than 90%

Atmospheric Pressure 86kPa-106kPa

AC 220V ±10%

Power 6KW

Frequency 50Hz±1Hz

Grounding resistance less than 4Ω can be connected to instrument control room

Vibration Requirement no strong vibration

Analyzer

ZRE

SO2 Measuring Range 0-500PPm /2500 PPm (extended)

Sampling Method Direct Extraction Method

Analytical Method  NDIR

Linearity Error ≤±1%

Repeatability ≤±0.5%

Drifting ≤±1% full range/week

Precision ≤1%

Response Time less than 60s

Air Requirement without

Alarm Output switch output

Output Signal Model 4~20mA

NOx Measuring Range 0-1000PPm /2500 PPm (extended)

Sampling Method Direct Extraction Method

Analytical Method NDIR

Linearity Error≤±1%

Repeatability ≤±0.5%

Drifting ≤±1% full range/week

Precision≤1%

Response Time less than 60s

Air Requirement without

Alarm Output switch output

Output Signal Model 4~20mA

O2 Measuring Range 0-25%

Sampling Method Direct Extraction Method

Analytical Method electrochemistry

Repeatability ≤±0.5%

Drifting ≤±1%full range/week

Precision ≤1%

Response Time <60S

Air Requirement without

Alarm Output switch output

Output Signal Model 4~20mA

Dust Measuring Device

TH-LRD801

Measuring Range 0~500 mg/m3/3000 mg/m3

Precision ≤±2%

Zero Drifting ≤±1.5%

Span Drift ≤±2%

Response Time ≤10s

Heating Sampler

TH-RC01

Temperature Range 0~200°C

Measurement error≤±1%

Control Accuracy ≤±1%

Supply Voltage ~220V

Dielectric Resistance >20MΩ

Heating Tracer

TH-200-3

Temperature Range 0~200°C

Power Supply ~220V

Gas Cooler

TH-QL03

Temperature Range -40~50°C

Measurement Accuracy ≤±1%

Power Supply  ~220V

Flue Gas parameters measurement subsystem

 

Velocity Measurement Device

Measurement Range 5~40m/s

Accuracy ≤±2%

Temperature Transmitter

Measurement Range 0~300°C

Accuracy:≤±1%

Pressure Transmitter

Measurement Range -10~10kPa

Accuracy ≤±1%

Data Collection Control Meter

TH-2000S

Output Voltage 180~240VAC

Rated Power 350W

Operating Temperature -10°C~50°C

Operating Humidity 5%-95%

Contrast Ratio 400/1

System Configuration Integrated Workstation

Dustproof Requirement IP54

Environment Air Temperature Limit 5°C~35°C

Compressed Air System

Compressed Air Requirement 0.8MPa

Maximal Air Flow 115m3/min

Average Gas Flow 80m3/min

Minimum Pressure 0.6 MPa